SLM MAXIMUM LOAD AT FULL EXTENSION (Tonnes) MOUNTED PIN TO PIN.
ROD BUCKLING MAY OCCUR IF THESE LOADS ARE EXCEEDED.
LOAD CAPABILITIES CAN BE INCREASED BY FITTING LARGER DIAMETER RODS. |
|
Calculations based on:
- "Euler" equation with safety factor of 2.0 (light-duty, no shock loads)
- Higher safety factors must be used in more arduous conditions.
- Cylinder is assumed to be vertical, with both ends fully guided, and no
allowance is made for friction in the clevis pins due to the cylinder
swinging through an arc.
|
BORE |
ROD |
LOAD IN TONNES FOR STANDARD STROKES (in inches) |
4 |
6 |
8 |
10 |
12 |
16 |
18 |
20 |
24 |
30 |
36 |
48 |
1.5" |
7/8" |
2.40 |
2.40 |
2.40 |
2.25 |
1.75 |
1.14 |
0.95 |
0.80 |
0.59 |
0.41 |
0.30 |
0.18 |
2.0" |
1.0" |
4.27 |
4.27 |
4.27 |
3.84 |
2.98 |
1.94 |
1.62 |
1.37 |
1.01 |
0.69 |
0.50 |
0.30 |
2.5" |
1.5" |
6.68 |
6.68 |
6.68 |
6.68 |
6.68 |
6.68 |
6.68 |
6.20 |
4.67 |
3.24 |
2.39 |
1.45 |
3.0" |
1.5" |
9.62 |
9.62 |
9.62 |
9.62 |
9.62 |
8.65 |
7.27 |
6.20 |
4.67 |
3.24 |
2.39 |
1.45 |
|